Now showing items 1-12 of 12

    • Moore, Robert Bowen (Texas A&M University. Libraries, 1988)
      High-performance liquid chromatographic procedures were used to study the ion-exchange selectivities of perfluorosulfonate ionomers (PFSI's). HPLC columns were packed with PFSI-coated octadecyl-derivatized silica and were ...
    • Chamkasem, Narong (Texas A&M University. Libraries, 1985)
      A high performance liquid chromatographic (HPLC) technique was developed to analyze gossypol in cottonseed products with higher sensitivity and specificity than the official spectrophotometric method. Seventy percent aqueous ...
    • Turner, Gordon Vincen (Texas A&M University. Libraries, 1982)
      Reference is made to the widespread occurrence of the mycotoxin zearalenone in feed ingredients and mixed feeds. The likelihood of zearalenone residues occurring in edible tissues of chickens fed a contaminated ration is ...
    • Ehrhardt, Kenneth Charle (Texas A&M University. Libraries, 1983)
      Arsenate, arsenite, methylarsonic acid and dimethylarsinic acid are arsenic compounds commonly found in the environment. An efficient method combining high performance liquid chromatography with a Hitachi-Zeeman graphite ...
    • College of Veterinary Medicine & Biomedical Sciences
    • College of Veterinary Medicine & Biomedical Sciences
    • College of Veterinary Medicine & Biomedical Sciences
      Liquid Chromotograph; the larger machine with multiple controls on the left is a, Model 440 Absorbance detector. This larger machine encases the smaller pump (Waters Associates, Inc. M-6000A), there is a second and identical ...
    • College of Veterinary Medicine & Biomedical Sciences
      Liquid Chromotograph; the larger machine with multiple controls on the left is a, Model 440 Absorbance detector. This larger machine encases the smaller pump (Waters Associates, Inc. M-6000A), there is a second and identical ...
    • College of Veterinary Medicine & Biomedical Sciences
      Liquid Chromotograph; the larger machine with multiple controls on the left is a, Model 440 Absorbance detector. This larger machine encases the smaller pump (Waters Associates, Inc. M-6000A), there is a second and identical ...
    • College of Veterinary Medicine & Biomedical Sciences
      Liquid Chromotograph; the larger machine with multiple controls on the left is a, Model 440 Absorbance detector. This larger machine encases the smaller pump (Waters Associates, Inc. M-6000A), there is a second and identical ...
    • College of Veterinary Medicine & Biomedical Sciences
      Liquid Chromotograph; the larger machine with multiple controls on the left is a, Model 440 Absorbance detector. This larger machine encases the smaller pump (Waters Associates, Inc. M-6000A), there is a second and identical ...
    • Shelly, Dennis Calvi (Texas A&M University. Libraries, 1982)
      A rapid scanning fluorometer is used for the fluorescence fingerprinting of bacteria and environmental pollutants. The fingerprint data are formatted as a two-dimensional array of fluorescence intensity as a function of ...