(Texas A&M University. Libraries, 1988)High-performance liquid chromatographic procedures were used to study the ion-exchange selectivities of perfluorosulfonate ionomers (PFSI's). HPLC columns were packed with PFSI-coated octadecyl-derivatized silica and were ...
-
(Texas A&M University. Libraries, 1985)A high performance liquid chromatographic (HPLC) technique was developed to analyze gossypol in cottonseed products with higher sensitivity and specificity than the official spectrophotometric method. Seventy percent aqueous ...
-
(Texas A&M University. Libraries, 1982)Reference is made to the widespread occurrence of the mycotoxin zearalenone in feed ingredients and mixed feeds. The likelihood of zearalenone residues occurring in edible tissues of chickens fed a contaminated ration is ...
-
(Texas A&M University. Libraries, 1983)Arsenate, arsenite, methylarsonic acid and dimethylarsinic acid are arsenic compounds commonly found in the environment. An efficient method combining high performance liquid chromatography with a Hitachi-Zeeman graphite ...
-
Liquid Chromotograph; the larger machine with multiple controls on the left is a, Model 440 Absorbance detector. This larger machine encases the smaller pump (Waters Associates, Inc. M-6000A), there is a second and identical ...
-
Liquid Chromotograph; the larger machine with multiple controls on the left is a, Model 440 Absorbance detector. This larger machine encases the smaller pump (Waters Associates, Inc. M-6000A), there is a second and identical ...
-
Liquid Chromotograph; the larger machine with multiple controls on the left is a, Model 440 Absorbance detector. This larger machine encases the smaller pump (Waters Associates, Inc. M-6000A), there is a second and identical ...
-
Liquid Chromotograph; the larger machine with multiple controls on the left is a, Model 440 Absorbance detector. This larger machine encases the smaller pump (Waters Associates, Inc. M-6000A), there is a second and identical ...
-
Liquid Chromotograph; the larger machine with multiple controls on the left is a, Model 440 Absorbance detector. This larger machine encases the smaller pump (Waters Associates, Inc. M-6000A), there is a second and identical ...
-
(Texas A&M University. Libraries, 1982)A rapid scanning fluorometer is used for the fluorescence fingerprinting of bacteria and environmental pollutants. The fingerprint data are formatted as a two-dimensional array of fluorescence intensity as a function of ...